Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Antonio F Corno
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tozzi, P.
Right arrow Articles by von Segesser, L. K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tozzi, P.
Right arrow Articles by von Segesser, L. K
Related Collections
Right arrow Coronary disease
Asian Cardiovasc Thorac Ann 2003;11:143-146
© 2003 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Intravascular Ultrasound: Potential Tool to Assess Coronary Anastomosis Quality

Piergiorgio Tozzi, MD, Antonio F Corno, MD, Ludwig K von Segesser, MD

Department of Cardiovascular Surgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland

For reprint information contact: Piergiorgio Tozzi, MD Tel: 41 21 3142280 Fax: 41 21 3142278 email: tozzig{at}hotmail.com Service de Chirurgie CardioVasculaire - BH10, Centre Hospitalier Universitaire Vaudois (CHUV), Rue du Bugnon, 46,1011–Lausanne, Switzerland.

Coronary angiography and Doppler flow measurements are most commonly used to assess the patency of anastomoses in the operating theater. Intravascular ultrasound might be another means of monitoring the surgical procedure during coronary artery bypass. Five sheep underwent off-pump bypass of the left anterior descending coronary artery using the left internal mammary artery. The running suture was evaluated by intraoperative fluoroscopy and a coronary intravascular ultrasound probe inserted into the target artery proximal to the anastomosis. Macroscopic examination of the anastomosis was performed to validate the angiographic and intravascular ultrasound images. The diameter, cross-sectional area, and compliance of each anastomosis were calculated in systole and diastole. All anastomoses were patent without signs of stenosis. In one case, intravascular ultrasound showed an intimal flap, which was confirmed by macroscopic examination. The mean major anastomotic diameter was 4.5 ± 0.5 mm on angiography and 4.0 ± 0.5 mm on intravascular ultrasound. From the ultrasound data, the mean cross-sectional anastomotic area was calculated as 6.21 ± 0.1 mm2 in systole and 5.49 ± 0.1 mm2 in diastole, and these data were used to calculate the cross-sectional anastomosis compliance. Coronary intravascular ultrasound can visualize intima-to-intima apposition and provide reliable calculations of anastomosis compliance.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
T. C. Dessing, R. P.J. Budde, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman
Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound
Eur. J. Cardiothorac. Surg., August 1, 2004; 26(2): 257 - 261.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by SAGE Publications