Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Alexander John
Mohammad Ali Manoutcheri
Virgilijus Ziaukas
Henning Warnecke
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by John, A.
Right arrow Articles by Warnecke, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by John, A.
Right arrow Articles by Warnecke, H.
Related Collections
Right arrow Valve disease
Asian Cardiovasc Thorac Ann 2004;12:213-217
© 2004 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTION

Aortic Valve Replacement with the Medtronic Freestyle Stentless Bioprosthesis

Alexander John, MD, Christoph Glauner, MD, Mohammad Ali Manoutcheri, MD, Virgilijus Ziaukas, MD, Gummiah Muniputtana Mahesh, MD, Henning Warnecke, MD

Department of Heart Surgery, Schuechtermann Klinik, Bad Rothenfelde, Germany

For reprint information contact: Alexander John, MD Tel: 49 54 2464 1651 Fax: 49 54 2464 1653 Email: htg{at}schuechtermann-klinik.de Schuechtermann Klinik, Ulmenallee 11, 49214 Bad Rothenfelde, Germany.

During a five-year period from 1996 to 2000, the Medtronic Freestyle stentless bioprosthesis was implanted in 310 patients of advanced age. Age at operation ranged from 60 to 90 years (mean, 76 ± 4 years). 191 patients were female and 119 male. All implants were done by the modified subcoronary method using our own modification which enabled an improved adaptation of the porcine aortic root to the human anatomy. Two sinuses were scalloped and the third left intact. Additional coronary bypass grafts were necessary in 129 (39%) patients and mitral valve procedures in 23 (7%). Mean perfusion time was 109 ± 12 minutes and crossclamp time 87 ± 8 minutes. 16 (5%) patients died perioperatively. Another 17 (5.7%) patients died during a 1 to 5.6 year follow-up (mean, 2.9 years). There was only one valve related death due to infection of the valve. In spite of the advanced age, 95% of the survivors were free from cardiac symptoms and continued to live an active and fruitful life. The biological nature of the valve and the low gradients are perhaps reasons for the good results. The long-term results are expected to be good.




This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. John, B. Al-Hariri, J. Ackemann, M. El-Mehsen, S. Roethemeyer, and H. Warnecke
Subcoronary Implantation of a Stentless Valve in Patients with Aortic Aneurysms
Asian Cardiovasc Thorac Ann, October 1, 2008; 16(5): 355 - 360.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. John, B. Al-Hariri, J. Ackemann, and H. Warnecke
Replacing the diseased aortic valve and the proximal aorta in the elderly patient
Eur. J. Cardiothorac. Surg., May 1, 2007; 31(5): 939 - 940.
[Abstract] [Full Text] [PDF]