Asian Annals Click here to go to Maquet website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hou, X.-T.
Right arrow Articles by Wang, J.-G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hou, X.-T.
Right arrow Articles by Wang, J.-G.
Related Collections
Right arrow Great vessels
Asian Cardiovasc Thorac Ann 2006;14:35-37
© 2006 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTION

Femoral Artery Cannulation in Stanford Type A Aortic Dissection Operations

Xiao-Tong Hou, MD, Yan-Qing Sun, MD, Hong-Jia Zhang, MD, Si-Hong Zheng, MD, Yu-Yong Liu, MD, Jian-Gang Wang, MD

Department of Cardiac Surgery, Beijing An Zhen Hospital, Capital University of Medical Science, Beijing, China

For reprint information contact: Xiao-Tong Hou, MD Tel: 86 10 6445 6384 Fax: 86 10 6838 9856 Email:houxiaotong{at}yahoo.com.cn, Department of Cardiac Surgery, Beijing An Zhen Hospital, Capital University of Medical Science, Beijing 100029, China.

The aim of this study was to evaluate femoral artery cannulation in Stanford type A aortic dissection operations. Between March 1994 and December 2001, 88 patients with Stanford type A aortic dissection underwent surgery with cardiopulmonary bypass and perfusion through the femoral artery; 31 of them had deep-hypothermic circulatory arrest. False lumen perfusion was detected in 8 patients (9.1%). There were 4 (4.5%) cerebral events: 2 patients had diffuse cerebral injury, with one death; and 2 patients had hemiplegia, with one death. Six patients (8.0%) had delayed incision healing, with local infection in one. There was no lower extremity ischemia associated with femoral artery cannulation. It was concluded that retrograde perfusion through the femoral artery was effective for repair of aortic dissection, with a low risk of those cerebral events associated with a high mortality rate.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 by the Asia Publishing EXchange Ltd.