Asian Annals Click here to go to Medistim website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Sven Beholz
Wolfgang Konertz
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beholz, S.
Right arrow Articles by Konertz, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beholz, S.
Right arrow Articles by Konertz, W.
Related Collections
Right arrow Valve disease
Asian Cardiovasc Thorac Ann 2006;14:128-133
© 2006 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Continuous Suture Technique for Freedom Stentless Valve: Reduced Crossclamp Time

Sven Beholz, PhD, Simon Dushe, MD, Wolfgang Konertz, PhD

Department of Cardiovascular Surgery, Charité–University Medicine Berlin, Berlin, Germany

For reprint information contact: Sven Beholz, PhD Tel: 49 30 450 522 196 Fax: 49 30 450 522 921 Email: sven.beholz{at}charite.de, Department of Cardiovascular Surgery, Charité-University Medicine Berlin, Luisenstr. 65, Berlin 10117, Germany.

The Pericarbon Freedom stentless valve has shown excellent hemodynamics. A continuous suture technique at the inflow site may reduce cardiopulmonary bypass and crossclamp times and affect postoperative hemodynamics. In a prospective case-matched study, interrupted and continuous suture line techniques were used in 68 and 71 patients, respectively. Isolated valve replacement was performed in 70.4% of the continuous suture group and 67.6% of the interrupted suture group. Hemodynamic data were obtained by echocardiography (mean and peak gradients, regurgitation) at discharge and after 1 year. Overall mortality was 5.0% and due to non-valve-related causes. Bypass and crossclamp times were shorter by 22.4 and 20.6 min, respectively, in the continuous suture group. The suture technique at the inflow site did not result in significant differences in the mean (11.8 ± 6.3 vs. 12.5 ± 6.2 mm Hg) or peak gradients (21.0 ± 9.6 vs. 22.0 ± 10.9 mm Hg), or degree of regurgitation. Follow-up showed a further decrease in the gradients.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. D'Onofrio, S. Auriemma, P. Magagna, A. Favaro, A. Cannarella, C. Piccin, M. Bilotta, N. Abbiate, N. Lamascese, and A. Fabbri
Aortic valve replacement with the Sorin Pericarbon Freedom stentless prosthesis: 7 years' experience in 130 patients
J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 491 - 495.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 by the Asia Publishing EXchange Ltd.