Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Rabin Gerrah
Gideon Merin
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gerrah, R.
Right arrow Articles by Varon, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gerrah, R.
Right arrow Articles by Varon, D.
Related Collections
Right arrow Coronary disease
Right arrow Extracorporeal circulation
Asian Cardiovasc Thorac Ann 2006;14:310-315
© 2006 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Using Cone and Plate(let) Analyzer to Predict Bleeding in Cardiac Surgery

Rabin Gerrah, MD, Alex Brill, PhD1, Sagi Tshori, MD2, Aharon Lubetsky, MD3, Gideon Merin, MD4, David Varon, MD1

Department of Cardiothoracic Surgery, Assuta Medical Center, Tel Aviv, Israel
1 Coagulation Unit, Department of Hematology
2 Department of Medical Biochemistry, Hebrew University, Hadassah Medical School, Jerusalem, Israel
3 Institute of Thrombosis and Hemostasis, Sheba Medical Center, Tel Hashomer, Israel
4 Department of Cardiothoracic Surgery, Hebrew University, Hadassah Medical School, Jerusalem, Israel

For reprint information contact: Rabin Gerrah, MD Tel: 972 3 520 1436 Fax: 972 3 520 1747 Email: rabin{at}assuta.com, Cardiothoracic Surgery, Assuta Medical Center, 62 Jabotinsky Street, Tel Aviv 62748, Israel.

The cone and plate(let) analyzer is an established method for assessing platelet function. It evaluates adherence of platelets on an extracellular matrix, expressed as a percentage of surface coverage and the average size of the aggregates. The purpose of this study was to determine the applicability of the cone and plate(let) analyzer in monitoring platelet function and predicting postoperative bleeding. The relationship between postoperative bleeding, perioperative platelet function, and other parameters was studied. A significant decrease in surface coverage was detected upon establishment of cardiopulmonary bypass (from 6.9% ± 3.9% to 4.7% ± 1.7%) with a return to preoperative values at the end of surgery. Preoperative average size and surface coverage were the only parameters that significantly and linearly correlated with postoperative bleeding. Patients with an aggregate average size < 20 µm2 had a significantly higher incidence of severe bleeding (> 965 mL) than those with a size > 20 µm2 (44% vs. 0%), and a higher mean blood loss (908 ± 322 mL vs. 337 ± 78 mL). Similar results were obtained for surface coverage < 5%, indicating the predictive value of these parameters. Preoperative platelet function as evaluated by the cone and plate(let) analyzer is an independent risk factor determining postoperative bleeding.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 by SAGE Publications