Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Omer Dzemali
Farhad Bakhtiary
Anton Moritz
Peter Kleine
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wittlinger, T.
Right arrow Articles by Kleine, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wittlinger, T.
Right arrow Articles by Kleine, P.
Asian Cardiovasc Thorac Ann 2008;16:278-283
© 2008 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Hemodynamic Evaluation of Aortic Regurgitation by Magnetic Resonance Imaging

Thomas Wittlinger, MD, Omer Dzemali, MD, Farhad Bakhtiary, MD, Anton Moritz, PhD, Peter Kleine, MD

Department of Thoracic and Cardiovascular Surgery, University Hospital, Frankfurt, Germany

For reprint information contact: Thomas Wittlinger, MD Tel: 49 69 6301 83315 Fax: 49 69 63013842 Email: thomaswittlinger{at}t-online.de, Department of Thoracic and Cardiovascular Surgery, University Hospital, Theodor-Stern Kai 7, 60590 Frankfurt, Germany.

Magnetic resonance imaging was compared with echocardiography and angiography in determining the regurgitant volume in patients with aortic regurgitation. Forty patients were examined at 1.5 T. The regurgitant jet was located using a gradient-echo sequence. Cine measurements were performed to calculate left ventricular function. For flow evaluation, a velocity-encoded breath-hold phase-difference magnetic resonance sequence was used. The degree of aortic regurgitation assessed by magnetic resonance imaging agreed with that of angiography in 28 of 40 (70%) patients, and with the echocardiography result in 80%. Correlation between calculated stroke volume by magnetic resonance cine and flow measurements was very good (r > 0.9). Magnetic resonance imaging enables quick and reliable quantitative assessment of aortic regurgitant volume, and it might be the optimal technique for multiple follow-up studies and assessment of left ventricular function, leading to better evaluation of disease severity and optimization of the timing of valve surgery.