Asian Annals Click here to go to Maquet website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Abbasali Karimi
Seyed Hesameddin Abbasi
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Karimi, A.
Right arrow Articles by Yazdanifard, P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Karimi, A.
Right arrow Articles by Yazdanifard, P.
Asian Cardiovasc Thorac Ann 2008;16:301-304
© 2008 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Mortality in Open Heart Surgery with Intraaortic Balloon Pump Support

Abbasali Karimi, MD, Namvar Movahedi, MD, Abbas Salehiomran, MD, Mehrab Marzban, MD, Seyed Hesameddin Abbasi, MD1, Parin Yazdanifard, MD1

Cardiothoracic Surgery Department
1 Clinical Research Department, Tehran Heart Center, Medical Sciences University of Tehran Tehran, Iran

For reprint information contact: Abbasali Karimi, MD, Tel: 98 21 8802 9256, Fax: 98 21 8802 9256, Email: abbasalikarimi2006{at}yahoo.com Tehran Heart Center, North Kargar Street, Tehran, Iran 1411713138.

Mechanical circulatory assistance is frequently needed to support the failing heart. The aim of this study was to determine perioperative prognostic factors for hospital mortality in patients undergoing open heart surgery who required intraaortic balloon pump support. Between January 2002 and September 2006, 475 patients received an intraaortic balloon pump perioperatively. Hospital mortality was 21.89%. Risk factors for hospital death identified by multivariate logistic regression analysis were peripheral vascular disease, left main coronary artery disease, postoperative renal failure, postoperative cardiac arrest, and prolonged hospital stay. Minor and major intraaortic balloon pump-related complications were not significant in univariate and multivariate analysis; the incidence was 5.05%. It is suggested that the threshold for using balloon pump support is decreased in high-risk patients undergoing cardiac surgery.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 by the Asia Publishing EXchange Ltd.