Asian Annals Click here to go to Maquet website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Praveen Kumar
Ravindra Setty
Devi P Shetty
Right arrow Permission Requests
Google Scholar
Right arrow Articles by Parachuri, V R.
Right arrow Articles by Shetty, D. P
PubMed
Right arrow PubMed Citation
Right arrow Articles by Parachuri, V R.
Right arrow Articles by Shetty, D. P
Asian Cardiovasc Thorac Ann 2008;16:401-406
© 2008 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Ventricular Restoration by Linear Endoventricular Patchplasty and Linear Repair

V Rao Parachuri, FRCS, Srilakshmi M Adhyapak, DNB, Praveen Kumar, MCh, Ravindra Setty, MCh, Ravi Rathod, MCh, Devi P Shetty, MS

Department of Cardiothoracic Surgery, Narayana Hrudayalaya, Bangalore, India

For reprint information contact: V Rao Parachuri, FRCS, Tel: 91 80 783 5000, Fax: 91 80 783 2648, Email: srili2881967{at}yahoo.com, Narayana Hrudayalaya, 258/A Bommasandra Industrial Area, Anekal Taluk, Bangalore 560099, India.

Surgical ventricular restoration improves cardiac function in patients with large left ventricular aneurysms. Aneurysm repair techniques have evolved to geometric repair by exclusion of the aneurysmal area with a circular patch. But even circular endoventricular patchplasty may result in a less elliptical ventricle. We modified the techniques of both linear and geometric repair. The early and intermediate outcomes in 102 patients with post-infarction left ventricular aneurysm, treated between 2001 and 2004, were analyzed. Concomitant procedures included coronary artery bypass grafting in 73 patients, mitral valve repair in 29, cryoablation in 3, and post-infarction ventricular septal rupture repair in 3. Overall mortality was 12.7%. Left ventricular ejection fraction increased significantly postoperatively, from 31.5% ± 6.5% to 34.2% ± 5.9%. There were significant decreases in end-diastolic volumes from 140.3 ± 38.3 to 100.8 ± 33.5 mL, and end-systolic volumes from 95.1 ± 26.1 to 66.0 ± 21.7 mL. These benefits continued at the 12- to 52-month follow-up. Our modified technique restores a near physiological left ventricular geometry and has a favorable clinical outcome.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 by the Asia Publishing EXchange Ltd.