Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ostovan, M. A
Right arrow Articles by Mirabadi, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ostovan, M. A
Right arrow Articles by Mirabadi, M.
Asian Cardiovasc Thorac Ann 2008;16:454-458
© 2008 Asia Publishing EXchange Ltd


ORIGINAL CONTRIBUTIONS

Experience with Paclitaxel-Eluting Infinnium Coronary Stents

Mohammad A Ostovan, MD, Reza Mollazadeh, MD, Javad Kojuri, MD, Mohammad Mirabadi, MD

Cardiology Department Nemazee Hospital, Shiraz University of Medical Science Shiraz, Iran

For reprint information contact: Reza Mollazadeh, MD Tel: 98 917 313 3749 Fax: 98 711 626 1089 Email: mollazar{at}yahoo.com, Cardiology Department, Nemazee Hospital, Zand Avenue, Shiraz, Iran. PO Box: 71435-1414.

To investigate the safety and efficacy of the Infinnium Paclitaxel-eluting stents in the treatment of coronary artery lesions, 196 patients with symptomatic coronary disease who received 202 stents at our center from January 2004 to November 2005 were studied prospectively. The primary study endpoint was the incidence of abnormalities on exercise electrocardiograms or cardiac single-photon emission tomography at 6 months, as a noninvasive index of stent reocclusion. Secondary endpoints were the rates of major adverse cardiac events at 1, 3, 6, 9, and 12 months. Stent deployment was successful in 98% of patients. Cumulative major adverse cardiac event rates at the end of 12 months were: cardiac death 1%, myocardial infarction 5% (Q-wave 2.5%, non-Q-wave 2.5%), and repeat revascularization of the stented lesion 3%. The overall major adverse cardiac event rate was 8.1%. There were 6 (3%) stent thromboses; all occurred late after the procedure. In patients with symptomatic ischemic heart disease, the low-cost Infinnium stent proved both effective and safe, with an acceptably low major adverse cardiac event rate.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 by SAGE Publications