Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniel Loisance
Matthias Kirsch
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sugiki, H.
Right arrow Articles by Kirsch, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sugiki, H.
Right arrow Articles by Kirsch, M.

ORIGINAL ARTICLE

Temporary Right Ventricular Support with Impella Recover RD Axial Flow Pump

Hiroshi Sugiki, PhD, Kuniki Nakashima, PhD, Emmanuelle Vermes, PhD, Daniel Loisance, MD, Matthias Kirsch, PhD

Department of Cardiothoracic Surgery Henri Mondor Hospital Créteil, France

Hiroshi Sugiki, PhD, Tel: +33 0149812111, Fax: +33 0149812199, Email: Hsugiki{at}aol.com, Department of Cardiothoracic Surgery, Henri Mondor Hospital, 51 Avenue du Mal de Lattre de Tassigny, 94010 Créteil Cedex, France.

ABSTRACT

Post-cardiotomy right ventricular failure is a serious complication that frequently results in adverse outcomes. We reviewed our experience with the Impella Recover RD (Impella Cardiosystems GMbH, Aachen, Germany). From January 2007 to December 2007, 7 patients (5 males, 54 +7 years old) had this device implanted for temporary support after heart transplantation in 4, after repeat mitral valve replacement in 2, and with a left ventricular assist device in 1. Devices were implanted during initial operation (n =5) or shortly thereafter (n =2). Six patients underwent implantation without cardiopulmonary bypass. Effective support with pump flows of 4.0–4.5 L · min–1 and adequate unloading (central venous pressure decreased from 15.3 ± 1.4 to 9.4 ± 1.2 mm Hg) was achieved in all patients. Patients were assisted for a mean duration of 4.9 ± 4.5 days. Three patients could be weaned after 7.0 ± 5.6 days of support and underwent device explantation without cardiopulmonary bypass. One of these patients died of recurrent right ventricular failure, 2 remained stable but died later of sepsis. The patient with a left ventricular assist device was switched to an alternative device for prolonged support. Two patients experienced pump dysfunction. Our preliminary experience shows that the Impella Recover RD is an effective device that can be easily implanted and explanted. However, its mechanical reliability needs to be improved.

Key Words: Ventricle-assist devices • Right ventricular dysfunction • Postcardiotomy cardiac dysfunction

Asian Cardiovasc Thorac Ann 2009; 17:395-400
© 2009 by SAGE Publications
DOI: 10.1177/0218492309338121






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 by SAGE Publications