Asian Annals Activate Your Online Account to Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jan Aagaard
Alexander S Geha
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aagaard, J.
Right arrow Articles by Geha, A. S
Right arrow Search for Related Content
PubMed
Right arrow Articles by Aagaard, J.
Right arrow Articles by Geha, A. S

ORIGINAL ARTICLE

Midterm Evaluation of Hemodynamics of the Top Hat Supraannular Aortic Valve

Jan Aagaard, MD1, Henrik Nissen, MD2, Alexander S Geha, MD3

1 Department of Cardiothoracic and Vascular Surgery
2 Department of Cardiology Odense University Hospital Odense, Denmark
3 Division of Cardiothoracic Surgery, University of Illinois Medical Center Chicago, IL, USA

Jan Aagaard, MD, Tel: +45 6541 1853, Fax: +45 6591 6935, Email: jan.aagaard{at}ouh.regionsyddanmark.dk, Department of Cardiothoracic and Vascular Surgery, Odense University Hospital, Soendre Boulevard 29, Odense, 5000 Denmark.

ABSTRACT

The CarboMedics Top Hat supraannular aortic valve provides an orifice-to-annulus ratio of 1:1 in most patients, and enhances patient outcomes. This study compared the midterm echocardiographic parameters of 52 patients undergoing aortic valve replacement with a Top Hat valve with those in other studies of Top Hat or CarboMedics intraannular valves. Echocardiography was performed 6–48 months after surgery with Top Hat sizes 21–27. Parameters evaluated included mean gradient, peak gradient, effective orifice area, and effective orifice area index. Preoperative and postoperative echocardiographic measurements were compared in 38 patients with aortic valve stenosis. Hemodynamic data were comparable to those of other studies, but the Top Hat prosthesis implanted was significantly larger (by a mean of 3.29 mm) than the valve size indicated using an intraannular valve sizer in 48 patients. Mean effective orifice area improved significantly from 0.73 cm2 preoperatively to 2.04 cm2 postoperatively. In patients with preoperative aortic valve stenosis, postoperative mean peak gradient was significantly reduced. The larger orifice-to-annulus ratio of the Top Hat valve improved hemodynamic parameters assessed by echocardiography up to 4 years postoperatively, with a lower transvalvular gradient, hence decreased left ventricular workload.

Key Words: Aortic Valve • Echocardiography • Heart Valve Diseases • Heart Valve Prosthesis • Hemodynamics

Asian Cardiovasc Thorac Ann 2010; 18:54-58