Asian Annals Click here to go to Maquet website
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mackey, S.
Right arrow Articles by Nuevo, F. R
Right arrow Search for Related Content
PubMed
Right arrow Articles by Mackey, S.
Right arrow Articles by Nuevo, F. R
Asian Cardiovasc Thorac Ann 1998;6:199-202
© 1998 Asia Publishing EXchange Pte Ltd


ORIGINAL CONTRIBUTION

Selection and Placement of Double-Lumen Tubes in Asian Patients

Sean Mackey, MD, PhD, Jay B Brodsky, MD, Teresa M Alcantara, MD1, James Monje, MD1, Florian R Nuevo, MD2

Department of Anesthesiology Stanford University School of Medicine Stanford, CA, USA
1 Section of Thoracic Anesthesia Lung Center of the Philippines Manila, Philippines
2 Division of Anesthesiology Santo Tomas University Hospital Manila, Philippines
For reprint information contact: Jay B Brodsky, MD Department of Anesthesiology, H-3580 Stanford University Medical Center Stanford, CA 94305, USA Tel: 1 650 723 6411 Fax: 1 650 725 8544 Email: Jbrodsky{at}leland.stanford.edu
In the first part of the study performed at Stanford University, 30 Asian born and 163 non-Asian born patients matched by height and weight had left-sided double-lumen tubes selected on the basis of the width of each patient's trachea. In the second part of the study performed at the Philippines Lung Center and Santo Tomas University Hospital, left-sided double-lumen tubes were selected on the basis of the anesthesiologists' clinical experience for 22 patients and by tracheal width guidelines for 35 patients. When tubes were selected by tracheal width, there was no difference between those used for Asian and non-Asian patients of similar size. We concluded that measurement of tracheal width can be used to select the appropriate size of left-sided double-lumen tubes for all patients.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by the Asia Publishing EXchange Ltd.