Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sreenivas Kumar, A.
Right arrow Articles by Srivastava, S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Sreenivas Kumar, A.
Right arrow Articles by Srivastava, S.
Asian Cardiovasc Thorac Ann 1999;7:204-208
© 1999 Asia Publishing EXchange Pte Ltd


ORIGINAL CONTRIBUTION

Percutaneous Occlusion of Patent Ductus Arteriosus with Controlled-Release Coil

Arramraj Sreenivas Kumar, MD, DM, Aditya Kapoor, MD, DM, Nakul Sinha, MD, DM, Madhukar Shahi, MD, DM, Pravin Kumar Goel, MD, DM, Sitaraman Radhakrishnan, MD, DM, Savitri Srivastava, MD, DM

Department of Cardiology
Sanjay Gandhi Post-Graduate Institute of Medical Sciences
Lucknow, India
For reprint information contact: Aditya Kapoor, MD, DM Tel: 91 522 44 0004 Ext 2225 Fax: 91 522 44 0017 email: akapoor{at}sgpgi.ac.in Department of Cardiology, Sanjay Gandhi Post-Graduate Institute of Medical Sciences, Raebareli Road, Lucknow 226014, India.
We evaluated the efficacy of the controlled-release Cook coil for percutaneous patent ductus arteriosus occlusion. Between October 1994 and December 1997, 45 consecutive patients with patent ductus arteriosus underwent cardiac catheterization and coil occlusion was attempted in 41, of whom 37 had Cook coils. A single coil was deployed in 34 of these patients and 2 or more coils were deployed in 3, with successful occlusion in 36 (97%). Immediate complete angiographic closure was achieved in 15 (41%), 18 (49%) had a trivial residual shunt, and 3 had a mild residual shunt on post-occlusion aortograms. Color Doppler echocardiography 24 hours after the procedure, revealed no detectable shunt in 33/36 (92%) and only a trivial residual shunt in 3 (8%) patients. Thus, 86% of patients with residual shunts immediately after occlusion had no evidence of residual shunts by 24 hours. No evidence of residual shunt or obstruction of the left pulmonary artery or the descending aorta was present at a mean follow-up of 26 months We concluded that Cook coils are a safe and cost-effective modality for percutaneous occlusion of patent ductus arteriosus with a high success rate and favorable intermediate-term follow-up.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by SAGE Publications