Asian Annals
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Takeo Tedoriya
Luc Tambeur
Roland Hetzer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tedoriya, T.
Right arrow Articles by Hetzer, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Tedoriya, T.
Right arrow Articles by Hetzer, R.
Related Collections
Right arrow Lung - transplantation
Asian Cardiovasc Thorac Ann 2001;9:257-259
© 2001 Asia Publishing EXchange Pte Ltd


ORIGINAL CONTRIBUTION

Coronary Artery Assessment by Epicardial Pulsed Doppler Ultrasound

Takeo Tedoriya, MD, Henrik Siniawski, MD, Luc Tambeur, MD, Michael Huebler, MD, Roland Hetzer, MD

Department of Cardiothoracic and Vascular Surgery German Heart Institute Berlin Berlin, Germany
For reprint information contact: Takeo Tedoriya, MD Tel: 81 86 235 7359 Fax: 81 86 235 7431 email: takeotedoriya{at}aol.comDepartment of Cardiovascular Surgery, Okayama University Medical School, 2-5-1 Shikata-cho, Okayama 700-8558, Japan.
An intraoperative method was developed for direct investigation of the coronary arteries using an epicardial high-frequency two-dimensional Doppler ultrasound transducer. This fingertip 7.5-MHz transducer was used in 30 patients undergoing coronary artery bypass surgery to measure blood flow in the coronary arteries and bypass grafts. In all the patients, clear images of the coronary arteries and the bypass grafts were obtained in the beating heart, and coronary blood flow could be measured to evaluate the degree of stenosis. There were no significant differences between the measurements obtained with the Doppler transducer and a transit-time ultrasonic flowmeter of blood flow in the left internal thoracic artery graft to the left anterior descending coronary artery, indicating that the Doppler method produces accurate and reproducible measurements. This method can provide useful intraoperative information about the coronary artery system in emergency operations such as acute aortic dissection.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Zilla, P. Human, M. Wolf, W. Lichtenberg, N. Rafiee, D. Bezuidenhout, N. Samodien, C. Schmidt, and T. Franz
Constrictive external nitinol meshes inhibit vein graft intimal hyperplasia in nonhuman primates
J. Thorac. Cardiovasc. Surg., September 1, 2008; 136(3): 717 - 725.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. Motallebzadeh, D. Batas, O. Valencia, V. Chandrasekaran, J. Smith, S. Brecker, and M. Jahangiri
The role of coronary angiography in acute type A aortic dissection
Eur. J. Cardiothorac. Surg., February 1, 2004; 25(2): 231 - 235.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 by SAGE Publications